Specifications
Description
Packaged Gas/Electric Unit, Type: Wired, Navigation, Power Source: 6VDC Supplied by Indoor Unit, Dimensions: 4.72 inch W x 0.75 inch D x 4.72 inch H, Humidity Range: 75% or Less (Without Condensation), Wiring Type: 2‐Wire/ DIII‐Net, For Use With: FXAQ, FXDQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXSQ, FXTQ, FXZQ VRV Indoor Unit Models, FAQ, FBQ, FCQ, FHQ, FTQ SkyAir Indoor Unit Models, Maximum Indoor Units: 16, Communication Wire: 18AWG‐2, No-Polarity Stranded, Non‐shielded, Total Wiring Length: 1640 ft, Communication Protocol: Daikin Proprietary P1P2 Protocol, Comfort Setpoint Range: 60 to 90 Deg F (16 to 32 Deg C), Operating Temp Range: 14 to 122 Deg F (‐10 to 50 Deg C), Control Type: Digital, Touchscreen: No, Programmable: Yes, Programming Options: 5-1-1, 5-2, 7 Day
Features
- Up to 16 indoor units are controllable in one group
- Can be combined with a secondary controller for dual operation
- Backlit LCD display in English, French, or Spanish
- Temperature sensor with configurable offset
- Display of temperature and setpoint in 1 Deg F/Deg C increments
- 3 display modes Detailed, Standard and Simple
- Dual setpoints (individual cooling and heating setpoints) with minimum setpoint differential or single setpoint (occupied period)
- Setpoint range limits for cooling and heating
- Independent cool/heat setback setpoints (unoccupied period)
- Auto changeover mode can automatically change to cool/heat mode at setpoint +/‐1 Deg F (can be configured from 1 to 4 Deg F using field settings) with a guard timer for 15, 30, 60 or 90 min. Surely change at another +/‐1 Deg F (can be configured from 1 to 4 Deg F using field settings) ignoring the guard timer
- Built in 7, 5+2, 5+1+1, and 1 (Everyday) schedule with up to 5 actions per day with independent cool/heat or setback setpoints
- Automatic adjustment for Daylight Savings Time (DST)
- 48 hour clock/calendar backup (in case of power failure)
- Constantly monitors the system for malfunctions with immediate display of fault location and condition
- Prohibit buttons on remote controller
- Limit selectable operation modes
- Display can be configured not to show setpoint when unit is Off. Display Off, instead of mode when unit is off. Fan speed display removable
- Backwards compatible