Description
Air Handler, High-Efficiency, Nominal Capacity: 1-1/2 ton, Filter Size: 16 inch x 20 inch, 208/240V Volt, 1.7A Amp, 1-Phase Phase, Frequency Rating: 60 Hz, Maximum Fuse Size: 15A, 600 to 1200 cfm, 19-3/4 inch Return Air Opening Depth, 15-7/8 inch Return Air Opening Width, Suction Line Size: 3/4 inch, Liquid Line Size: 3/8 inch, 10-5/16 inch Supply Opening Depth, 16 inch Supply Opening Width, 17-1/2 inch Width, 42-1/2 inch Height, 21-11/16 inch Depth, Standards: UL & cUL Listed, AHRI Certified, Includes: PSC Motor, 1075 rpm RPM, Horse Power: 1/5 HP, R-410A Refrigerant, 13 SEER
Features
- The most compact unit design available, all standard heat air handler models only 421/2 to 551/2 inches [1079 to 1409 mm] high.
- Attractive pre-painted cabinet exterior.
- Rugged wall steel cabinet construction, designed for added strength and versatility.
- 1 inch foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance.
- Four leg blower motor mount.
- Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience.
- Traditional open wire element design for heat applications.
- Field convertible for vertical downflow, horizontal left hand or right hand air supply.
- 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors.
- Indoor coil design provides low air side pressure drop, high performance and extremely compact size.
- Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil.
- Coils are constructed of aluminum fins bonded to internally grooved copper tubing.
- Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils.
- Supply duct flanges provided as standard on air handler cabinet.
- Provisions for field electrical, connections available from either side or top of the air handler cabinet.
- Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.
- Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 11/2 inch [38 mm] conduit.
- Front refrigerant and drain connections.
- Suitable for application in mobile homes.