Rinnai® EX08C 83% AFUE Variable Speed Inducer Liquid Propane Wall Furnace, 3000 to 8000 BTUH Input, 2400 to 6400 BTUH Output
Mfg Part #: EX08CLP
Part #: RINEX08CLP
Sold As: 1/Each
CPN: Add CPN
Specifications
Description
Wall Furnace, Gas Fired, Liquid Propane Gas, 120VAC Voltage Rating, Frequency Rating: 60 Hz, 42W Power, 1 Phase, Heating Capacity Input: 2400 to 6400 BTUH, Heating Capacity Output: 3000 to 8000 BTUH, 83% AFUE Efficiency, Electronic Spark Ignition Ignition, 27-3/8 inch Height, 10-1/8 inch Length, 18-1/4 inch Width, Beige, 1.5 pt Enameled Humidifier Tray, Noise Level: 27 to 36dB, <1W Stand by Power, Clearance: 2 inch Side, 40 inch Front, Direct Vent, 3-1/8 inch Concentric Vent Dia., Stainless Steel Bunsen Burners Combustion System, Gas Supply Pressure: 8 to 13 inch WC, Gas Connection: 1/2 inch NPT, 55.5 to 82 cfm Air Flow, Temperature Rise Range: 60 to 80 Deg F, Variable Speed Inducer Motor, 10 yr for Heat Exchanger, 5 yr for Parts, 2 yr for Labor Service Manufacturer Warranty, For Homes, Apartments and Condominiums, Residential or Commercial Setting Applications, CSA Certified Standards/Approvals
Features
- New cabinet design
- New user friendly control
- Temperature setting in celsius or fahrenheit
- Programmable thermostat
- Sealed combustion
- Cool to the touch cabinet
- 7-state modulating gas valve and variable speed blower
- Restart capability, restarts automatically when ignition or combustion fails
- Timer settings starts and turns off the heater at 2 timer settings
- Negative coefficient thermistor, detects temperature change in 1/2 of a Deg
- Variable speed inducer motor with pressure switch monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph
- Self diagnostic electronics continually monitors functions, provides auto shutdown codes to indicate when air filter needs cleaning
- Quiet operation reduces noise through use of swept blades in convection fan; and through the design of the combustion chamber and heat exchanger which silently expand or contract due to temperature changes
- Flame rod detects flame failure, results in auto shutdown to prevent escape of gas
- Bi-metal switch, thermal fuse, and thermistor detect overheat condition results in auto shutdown
- 3A fuse protects against power surge, results in auto shutdown
- Abnormal spark at time of ignition results in auto shutdown
- Combustion fan purges any gas from the combustion chamber before ignition
- Convection fan continues to run after burner shutdown to cool internal parts
- Child lock prevents inadvertent operation