Samsung AQX36VFUAGM/CV6 1-Phase R-410A 18 SEER 36000 BTUH Outdoor Mini-Split Air Conditioner
Mfg Part #: AQX36VFUAGM/CV6
Part #: AQX36VFUAGMCV6
Sold As: 1/Each
CPN: Add CPN
Specifications
Description
Mini-Split Air Conditioner, Nominal Cooling Capacity: 36000 BTUH, Nominal Heating Capacity: 36000 BTUH, SEER Rating: 18, EER Rating: 10.8, Voltage Rating: 208/230V, Frequency Rating: 60 Hz, Noise Rating: 58 dB, Current Rating: 3.6/14.2/18A (Cooling), 3.3/14.5/21A (Heating), Phase: 1, Unit Type: Outdoor, Line Set Size: 10 to 164 ft, Liquid Line Diameter: 1/4 inch, Suction Line Diameter: 5/8 inch, Refrigerant Type: R-410A, Breaker Size: 30A, Rated Load Amps: 13.8A (Compressor), Condensate: 8.45 pt/hr, 11/16 inch OD Connection, Control: Electronic Expansion, Minimum Circuit Amperage: 19.5A, Mounting: Wall, Valve Type: Electronic Expansion, Temperature Rating: 14 to 115 Deg F (Cooling), -5 to 75 Deg F (Heating), Compressor Type: DC, Inverter Driven, Rotary, Wire Size: 16 AWG, Capacity in Tons: 3 tons, Dimensions: 36-11/16 inch W x 45-7/8 inch H x 14-3/4 inch D, Warranty: 5 yr for Compressor, 3 yr for Parts, 120 Day Limited for Labor, HSPF: 9, Refrigerant Charge: 88.1 oz, Applications: For Sun Rooms, Wine Cellars, Guest Quarters, Garage Workshops, Homes Without Duct Work, Bedrooms and Family Rooms, Room Additions and Renovations, Storage Facilities, Hotels and other Lodging, Computer Rooms/Server Rooms, Offices in Warehouse Spaces, Restaurant Kitchen and Prep Areas, Buildings where Security Concerns Prevent the use of Window Units, Internal Areas without Exterior Wall Access Applications, Commercial add on Jobs where the Existing Air Conditioning System Cannot be Stretched, Historical Renovations or Any Application where Preserving the Look of the Original Structure is Crucial, Standards/Approvals: AHRI Certified, ETL Listed
Features
- Low ambient control built-in
- Outdoor unit shall provide 208/230V power to indoor unit via (3) 14 AWG interconnect power cable
- Electro static, washable, HD (high density) main filter as standard
- Chassis shall be galvanized steel with a baked on powder coated finish for durability
- The heat exchanger shall be mechanically bonded fin to copper tube
- Auto restart
- Turbo mode (during cooling operation only)
- Auto changeover
- 24 hr timer
- Good sleep mode, quiet mode, dry mode
- Control signal shall be DDC type signal
- The compressor shall be hermetically sealed, inverter controlled, twin BLDC rotary
- Refrigerant flow shall be controlled by EEV (electronic expansion valve) at outdoor unit
Resources
Branch Availability
Related Products
View category
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability