Samsung Hylex™ AC060BXUPCH/AA Inverter Driven Heat Pump Condensing Unit, 208 to 230 V, 33.2 A, 1 ph Phase, Steel
Mfg Part #: AC060BXUPCH/AA
Part #: SAMAC060BXUPCHAA
Sold As: 1/Each
CPN: Add CPN
Specifications
Description
Samsung Hylex™ Inverter Driven Heat Pump Condensing Unit, 208 to 230 V, 33.2 A, 125 W Power, 60 Hz Frequency, 1 ph, Number of Fan Speeds: 3, Heating BTU Rating: 14000 to 65000 Btu/hr, Cooling BTU Rating: 17700 to 59000 Btu/hr, Heating CFM Rating: 4414 cfm, Cooling CFM Rating: 4414 cfm, 9 EER, 17.5 SEER, 10.5 HSPF, Twin BLDC Rotary Compressor, R-410A Refrigerant, 3/8 in Liquid Line, 3/4 to 1-1/8 in Suction Line, 40 A Fuse, Inverter Drive, Heating Sound Level: 58 dB, Cooling Sound Level: 56 dB, Steel, Baked-On Powder-Coated/Galvanized, Heating Operating Temperature: -13 to 75 deg F, Cooling Operating Temperature: 23 to 125 deg F, 37 in Overall Width, 55-15/16 in Overall Height, Additional Information: 13 in D
Features
- Inverter driven heat pump condensing unit compatible with air handling units and A coils with a thermostatic expansion valve
- 100% rated heating capacity at 5 deg F outside temperature (refer to capacity tables in outdoor unit technical data book for full capacity details)
- Soft start compressor minimizing current inrush
- Base pan heater equipped as standard
- The condensing unit heat exchanger salt spray test method ISO 9227
- The heat exchanger showed no unusual rust or corrosion development to 3000 hr
- The system (outdoor unit with MXD-U000XN AHU control unit) shall provide three-fan speed control of the indoor unit increasing performance and dehumidification
- Refrigerant pipe connections and service ports are located inside the heat pump cabinet
- Refrigerant pipes can enter the cabinet on the front, side, back or bottom
- Requires MXD-U000XN AHU control unit (purchased separately) installed near the indoor unit for operation
- Control wiring shall be 2 x 18 AWG
- Compatible with standard 24 V thermostats
- Requires B reversing valve signal (24 V energized for heating)
- The compressor shall be hermetically sealed, inverter controlled, BLDC rotary
- The outdoor unit heat exchanger shall be mechanically bonded aluminum fin to copper tube
- Uses traditional unitary line sets (liquid pipe does not require insulation)
- Flexible pipe diameter compatibility (three suction pipe diameter options)
- Refrigerant flow shall be controlled by an electronic expansion valve in the outdoor unit for heating operation
- Refrigerant flow for cooling shall be controlled via thermostatic
- Expansion valve (TXV) at the indoor coil (bleed or non-bleed)
Branch Availability