

Rheem® RHMV 1-Phase Up to 17-SEER 18000 to 24000 BTUH 600 to 1200 CFM Standard Efficiency EcoNet Enabled Air Handler
Mfg Part #: RHMV2417SEACJA
Part #: RHRHMV2417SEACJA
Sold As: 1/Each
CPN: Add CPN
Specifications
Description
Air Handler, Series: RHMV, Type: Standard Efficiency, Modulating, EcoNet Enabled, Nominal Capacity: 18000 to 24000 BTUH, Air Flow: 600 to 1200 CFM, Voltage Rating: 208/240V, Frequency Rating: 60 Hz, Phase: 1, SEER Rating: Up to 17, Suction Line Size: 3/4 inch, Liquid Line Size: 3/8 inch, Length: 21-11/16 inch, Width: 17-1/2 inch, Height: 42-1/2 inch, Motor Type: Constant CFM Variable Speed (ECM), Finish: Attractive Pre-Painted Cabinet Exterior, Material: Rugged Wall Steel Cabinet, Filter Size: 16 inch x 20 inch, Return Air Opening Depth: 19-3/4 inch, Return Air Opening Width: 15-7/8 inch, Blower Dimensions: 10 inch x 8-1/3 inch, Warranty: 10 yr for Parts, Metering Device: EEV, Controls: Communicating
Features
- Equipped standard with an EcoNet air handler control board that allows it to directly communicate with the EcoNet control center
- Equipped with an electronic expansion valve (EEV), which can intelligently change the EEV position based on system demands
- Attractive pre-painted cabinet exterior
- Rugged wall steel cabinet construction, designed for added strength and versatility
- 1 inch foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance
- Four leg blower motor mount
- Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience
- Traditional open wire element design for heat applications
- Field convertible for vertical downflow, horizontal left hand or right hand air supply
- 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors
- Indoor coil design provides low air side pressure drop, high performance and extremely compact size
- Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing
- Coils are tested at the factory with an extensive refrigerant leak check
- Coils have copper sweat refrigerant connections
- Coils utilize chatleff metering device connections
- Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils
- Supply duct flanges provided as standard on air handler cabinet
- Provisions for field electrical, connections available from either side or top of the air handler cabinet
- Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet
- Front refrigerant and drain connections
Resources
No product resources were supplied for this item.
Branch Availability
Related Products
View category
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability
