Rheem® RHSL High Efficiency 13 SEER R-410A Air Handler, 4 Ton
Mfg Part #: RHSL-HM4821JA
Part #: RHRHSLHM4821JA
Sold As: 1/Each
CPN: Add CPN
Specifications
Description
Air Handler, High-Efficiency, Nominal Capacity: 4 ton, Filter Size: 25 inch x 20 inch, 208/240V Volt, 5.2A Amp, 1-Phase Phase, Frequency Rating: 60 Hz, Maximum Fuse Size: 15A, 1200 to 1600 cfm, 19-3/4 inch Return Air Opening Depth, 19-3/8 inch Return Air Opening Width, Suction Line Size: 7/8 inch, Liquid Line Size: 3/8 inch, 10-5/16 inch Supply Opening Depth, 19-1/2 inch Supply Opening Width, 21 inch Width, 50-1/2 inch Height, 21-11/16 inch Depth, Standards: UL & cUL Listed, AHRI Certified, Includes: PSC Motor, 1075 rpm RPM, Horse Power: 3/4 HP, R-410A Refrigerant, 13 SEER
Features
- The most compact unit design available, all standard heat air handler models only 421/2 to 551/2 inches [1079 to 1409 mm] high.
- Attractive pre-painted cabinet exterior.
- Rugged wall steel cabinet construction, designed for added strength and versatility.
- 1 inch foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance.
- Four leg blower motor mount.
- Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience.
- Traditional open wire element design for heat applications.
- Field convertible for vertical downflow, horizontal left hand or right hand air supply.
- 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors.
- Indoor coil design provides low air side pressure drop, high performance and extremely compact size.
- Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil.
- Coils are constructed of aluminum fins bonded to internally grooved copper tubing.
- Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils.
- Supply duct flanges provided as standard on air handler cabinet.
- Provisions for field electrical, connections available from either side or top of the air handler cabinet.
- Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.
- Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 11/2 inch [38 mm] conduit.
- Front refrigerant and drain connections.
- Suitable for application in mobile homes.
Resources
No product resources were supplied for this item.
Branch Availability
Related Products
View category
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability
EachSign in for Availability